DRINKING WATER TURBINE - REFERENCES

DRINKING WATER HPP BIRKENSTEIN
Customer:
Gemeinde Fischbachau, Bavaria, Germany
Turbine type:
1-nozzle drinking water Pelton turbine
Head (H):
220 m
Flow rate (Qmax):
50 l/sec
Power (P):
93 kW
DRINKING WATER HPP PADASTERTAL
Customer:
Arge Padastertal, Hall in Tirol für BBT Steinach am Brenner, Tirolo, Austria
Turbine type:
1-nozzle drinking water Pelton turbine
Head (H):
342 m
Flow rate (Qmax):
18 l/sec
Power (P):
53 kW
DRINKING WATER HPP GRUBERWIESEN-NOCKBACH
Customer:
Fernwärme Vahrn-Brixen Konsortial GmbH, South Tirol, Italy
Turbine type:
1-nozzle drinking water Pelton turbine
Head (H):
230 m
Flow rate (Qmax):
40 l/sec
Power (P):
79 kW
Turbine type:
2-nozzle drinking water Pelton turbine
Head (H):
134 m
Flow rate (Qmax):
88 l/sec
Power (P):
102 kW
DRINKING WATER HPP SCHLEIS
Customer:
Gemeinde Mals, South Tirol, Italy
Turbine type:
1-nozzle drinking water Pelton turbine
Head (H):
781 m
Flow rate (Qmax):
12,7 l/sec
Power (P):
86 kW
DRINKING WATER HPP SCHALDERS MITTE
Customer:
Fernwärme Vahrn-Brixen Konsortial GmbH, South Tirol, Italy
Turbine type:
1-nozzle drinking water Pelton turbine
Head (H):
322 m
Flow rate (Qmax):
100 l/sec
Power (P):
278 kW
DRINKING WATER HPP MUNTLERENTSCH, RAPPENSTALL; SCHALMENLITTEN
Customer:
Technische Betriebe Grabs, Grabs, Svizzera
Turbine type:
1-nozzle drinking water Pelton turbine
Head (H):
165 m
Flow rate (Qmax):
20 l/sec
Power (P):
27 kW
Turbine type:
1-nozzle drinking water Pelton turbine
Head (H):
110 m
Flow rate (Qmax):
18 l/sec
Power (P):
16 kW
Turbine type:
1-nozzle drinking water Pelton turbine
Head (H):
109 m
Flow rate (Qmax):
18 l/sec
Power (P):
16 kW